Applied Thermal Control (ATC) are well established in the scientific instrument support markets (electron microscopes, X-ray diffraction, ICPMS etc.), semiconductor process, ophthalmic lens manufacturing equipment, machine tool, and more recently the chillers of choice for commercial digital printing and laser lithography markets worldwide.
Applied Thermal Control’s air blast cooler units are supplied with the following:
- Supplied complete with circuit breakers and on/off switches
- Fan and coolant pump starting contactors
- Fan and coolant pump motor protection
- IP54 protection
- 24V control circuit where fitted
- Temperature gauge
- Pressure gauge
- Coolant safety bypass
- Visual tank level indicator
Additional options can be supplied, contact our team to discuss your requirements.
Applications
- TIG welding
- MIG welding
- Resistance welding machines
- High frequency generators
- Furnace equipment
- General process cooling
A Series 0-10kw
|
A01 Air Blast |
A03 Air Blast |
A05 Air Blast |
A10 Air Blast |
Normal capacity, set point 10°C above ambient,
and 10°C change in water temp |
1kW |
3kW |
5kW |
10kW |
TE Model Number |
AB COMPACT 10 |
AB COMPACT 30 |
AB COMPACT 50 |
AB100 |
Part Numbers |
A010200
A010300
|
A030300
A030303
A030500
A030503 |
A050500
A050503
A051000
A051003 |
A102540
A102543
|
Physical Attributes |
Physical Dimensions (mm) |
W410 x D380 x H550 |
W520 x D470 x H650 |
W600 x D600 x H770 |
W760 x D640 x H1180 |
Construction |
Sheet steel gauge 1.5mm
Support weight of unit from back or side edges
Epoxy polyester powder coated |
Sheet steel gauge 1.5mm
Support weight of unit from back or side edges
Epoxy polyester powder coated |
Sheet steel gauge 1.5mm
Support weight of unit from back or side edges
Epoxy polyester powder coated |
Sheet steel gauge 1.5mm
Support weight of unit from back or side edges
Epoxy polyester powder coated |
Acceptable Environment |
Indoors |
Indoors |
Indoors |
Indoors or outdoors sheltered |
Toolless Access |
No |
No |
No |
No |
Temperature Control Attributes |
Technology |
Air Blast |
Air Blast |
Air Blast |
Air Blast |
Control Method |
None, continuous fan |
None, continuous fan |
None, continuous fan |
None, continuous fan |
Temperature stability |
Load and ambient dependent |
Load and ambient dependent |
Load and ambient dependent |
Load and ambient dependent |
Cooling capacity with ‘setpoint’ 5°K above ambient |
0.5kW |
1.5kW |
2.5kW |
5kW |
Cooling capacity with ‘setpoint’ 10°K above ambient |
1kW |
3kW |
5kW |
10kW |
Cooling capacity with ‘setpoint’ 20°K above ambient |
2kW |
6kW |
10kW |
20kW |
Design ambient |
+25°C |
+25°C |
+25°C |
+25°C |
Rated collant outlet temperature |
+35°C |
+35°C |
+35°C |
+35°C |
Maximum ambient |
+50°C |
+50°C |
+50°C |
+50°C |
Design flowrate |
4L/min |
4L/min |
8.3L/min |
8.3L/min |
Maximum THR (Total Heat Rejection) |
Applied load, plus power in |
Applied load, plus power in |
Applied load, plus power in |
Applied load, plus power in |
Water Circuit Attributes |
Maximum permissible return line temperature |
+80°C |
+80°C |
+80°C |
+80°C |
Pressure relief |
Banjo flow control valve |
Banjo flow control valve |
Banjo flow control valve |
Banjo flow control valve |
Standard fittings |
1/2″ BSPPF |
1/2″ BSPPF |
1/2″ BSPPF |
3/4″ BSPPF |
Standard chemical compatibility |
Tap water, water-glycol mix |
Tap water, water-glycol mix |
Tap water, water-glycol mix |
Tap water, water-glycol mix |
A Series 20-80kw
|
A20 Air Blast |
A40 Air Blast |
A80 Air Blast |
Normal capacity, set point 10°C above ambient,
and 10°C change in water temp |
20kW |
40kW |
80kW |
TE Model Number |
AB200 |
AB400 |
AB800 |
Part Numbers |
A202543
A010300
|
A404043
A408043
|
A80
|
Physical Attributes |
Physical Dimensions (mm) |
W900 x D810 x H1761 |
W900 x D1060 x H1761 |
W1350 x D1260 x H2247 |
Construction |
Sheet steel gauge 1.5mm
Body covers in 1.2mm
Floor standing
Epoxy polyester powder coated |
Sheet steel gauge 1.5mm
Body covers in 1.2mm
Floor standing
Epoxy polyester powder coated |
Sheet steel gauge 1.5mm
Body covers in 1.2mm
Floor standing
Epoxy polyester powder coated |
Acceptable Environment |
Indoors or outdoors sheltered |
Indoors or outdoors sheltered |
Indoors or outdoors sheltered |
Toolless Access |
No |
No |
No |
Temperature Control Attributes |
Technology |
Air Blast |
Air Blast |
Air Blast |
Control Method |
None, continuous fan |
None, continuous fan |
None, continuous fan |
Temperature stability |
Load and ambient dependent |
Load and ambient dependent |
Load and ambient dependent |
Cooling capacity with ‘setpoint’ 5°K above ambient |
10kW |
20kW |
40kW |
Cooling capacity with ‘setpoint’ 10°K above ambient |
20kW |
40kW |
80kW |
Cooling capacity with ‘setpoint’ 20°K above ambient |
40kW |
80kW |
160kW |
Design ambient |
+25°C |
+25°C |
+25°C |
Rated collant outlet temperature |
+35°C |
+35°C |
+35°C |
Maximum ambient |
+50°C |
+50°C |
+50°C |
Design flowrate |
40L/min |
80L/min |
120L/min |
Maximum THR (Total Heat Rejection) |
Applied load, plus power in |
Applied load, plus power in |
Applied load, plus power in |
Water Circuit Attributes |
Maximum permissible return line temperature |
+80°C |
+80°C |
+80°C |
Pressure relief |
Quarter turn ball valve |
Quarter turn ball valve |
Quarter turn ball valve |
Standard fittings |
BSPPF |
– |
– |
Standard chemical compatibility |
Tap water, water-glycol mix |
Tap water, water-glycol mix |
Tap water, water-glycol mix |