Isolating & Safety Transformers for Industrial Applications
Browse our large range of isolating and safety transformers up to 40kVA designed specifically for industrial applications.
Three Phase Isolating & Safety Transformers for Industrial Applications
Suitable for any industrial application that requires separation between the load and the net
Meth Srl provides a large range of isolating and safety transformers up to 40kVA designed for industrial applications. Meth Srl’s isolating transformers with galvanic isolation provide a reliable supply to circuits with the safety measure protective separation. The transformers provide reinforced isolation between primary or secondary sides and can customise voltages, regulations, enclosures, wheels for movement and vibration absorbers.
T3T – up to 40kVA
The T3T low voltage three-phase isolating and safety transformers are suitable for any industrial application where separation between the load and the net is required.
Rated Input Voltage: 100-600V
Rated Output Voltage: 24-600V
Rated Power: up to 25kVA (safety transformers)
up to 40kVA (isolating transformers)
Insulation Class: class F/H
Temperature Class: class F/H
Ambient Temperature: Ta=40°C
Protection Degree: IP 00
Standard Vector Group: Dyn11 (others available upon request
Test Voltage: 4.2KV/1’
Terminals: terminal block or bars
Standards
– CEI-EN 61558; p.2-4 – isolating transformers
– CEI-EN 61558; p.2-6 – safety transformers
– IEC 61558; 2-4
Customisations
The T3T transformers can be customised with the following:
– Different voltages
– Regulations
– Taps on primary or secondary
– Different enclosures
– Wheels for movement
– Vibration absorbers
– Electrostatic screen between primary and secondary
– Temperature control unit with 3PT100 probes inserted
T3T up to 40kVA Technical Data
Part Number | Rated Power (KVA) | Insulation Class | Dimensions (mm) | Weight (Kg) | ||||
A | B | C | D | E | ||||
T3T-0.1 | 0.1 | F | 120 | 75 | 110 | 100 | 50 | 2.1 |
T3T-0.16 | 0.16 | F | 120 | 85 | 110 | 100 | 60 | 2.8 |
T3T-0.25 | 0.25 | F | 151 | 95 | 150 | 125 | 60 | 3.8 |
T3T-0.4 | 0.4 | F | 151 | 110 | 150 | 125 | 75 | 5.5 |
T3T-0.5 | 0.5 | F | 180 | 120 | 190 | 150 | 72 | 6.7 |
T3T-0.75 | 0.75 | F | 180 | 140 | 190 | 150 | 92 | 10.9 |
T3T-1 | 1 | F | 240 | 145 | 260 | 200 | 80 | 15 |
T3T-1.5 | 1.5 | F | 240 | 155 | 260 | 200 | 90 | 17.6 |
T3T-2 | 2 | F | 240 | 170 | 260 | 200 | 100 | 24.8 |
T3T-2.5 | 2.5 | F | 240 | 185 | 260 | 200 | 115 | 28.1 |
T3T-3 | 3 | F | 300 | 160 | 315 | 250 | 91 | 33 |
T3T-4 | 4 | F | 300 | 170 | 315 | 250 | 101 | 39 |
T3T-5 | 5 | F | 300 | 190 | 315 | 250 | 121 | 49 |
T3T-6 | 6 | F | 360 | 170 | 365 | 300 | 106 | 58 |
T3T-7 | 7 | F | 360 | 180 | 365 | 300 | 116 | 62 |
T3T-8 | 8 | F | 360 | 190 | 365 | 300 | 126 | 66 |
T3T-9 | 9 | F | 360 | 200 | 365 | 300 | 136 | 69 |
T3T-10 | 10 | F | 360 | 210 | 365 | 300 | 146 | 75 |
T3T-15 | 15 | F | 420 | 250 | 420 | 375 | 150 | 89 |
T3T-20 | 20 | F | 420 | 270 | 420 | 375 | 172 | 110 |
T3T-25 | 25 | F | 480 | 270 | 450 | 440 | 180 | 125 |
T3T-30 | 30 | F | 480 | 280 | 450 | 440 | 190 | 145 |
T3T-40 | 40 | F | 480 | 315 | 450 | 440 | 220 | 178 |
T3T – up to 40kVA Electrical Data
Rated Power (KVA) | Losses (W) | Efficiency (%) | Ucc (%) | Inrush Current (x in) | ||||
no-load | load 75°C | Total | Ucc X | Ucc R | Ucc tot | |||
0.1 | 5 | 15 | 20 | 83 | – | – | 13.5 | 24 |
0.16 | 6.5 | 19.5 | 26 | 85.8 | – | – | 10.9 | 25 |
0.25 | 7.5 | 24 | 31.5 | 88.4 | – | – | 9 | 26 |
0.4 | 11.5 | 38 | 49.5 | 88.6 | – | – | 8.8 | 24 |
0.5 | 15 | 26.5 | 41.5 | 92.2 | – | – | 5.1 | 22 |
0.75 | 22.5 | 30 | 52.5 | 93.3 | – | – | 3.9 | 25 |
1 | 25.8 | 42 | 67.8 | 93.6 | – | – | 4.2 | 18 |
1.5 | 30 | 64.5 | 84.5 | 93.9 | – | – | 4.2 | 18 |
2 | 37.5 | 102 | 139.5 | 93.4 | – | – | 4.8 | 17 |
2.5 | 46 | 114 | 160 | 93.9 | – | – | 4.4 | 15 |
3 | 47 | 129 | 176 | 94.3 | – | – | 4.2 | 15 |
4 | 58 | 186 | 244 | 94.2 | – | – | 4.5 | 15 |
5 | 76 | 169 | 245 | 95.3 | – | – | 3.4 | 16 |
6 | 84 | 300 | 384 | 94 | – | – | 5.2 | 14 |
7 | 100 | 285 | 385 | 94.7 | – | – | 4.4 | 15 |
8 | 110 | 355 | 465 | 94.5 | – | – | 4.5 | 15 |
9 | 122 | 384 | 506 | 94.7 | – | – | 4.3 | 15 |
10 | 135 | 387 | 522 | 95.06 | 1.46 | 4.3 | 4.55 | 16 |
15 | 192 | 440 | 632 | 96.22 | 1.7 | 3.17 | 3.6 | 16 |
20 | 140 | 570 | 710 | 96.78 | 1.68 | 2.6 | 3.1 | 16 |
25 | 160 | 720 | 880 | 96.6 | 2.77 | 2.88 | 4 | 18 |
30 | 190 | 800 | 990 | 96.81 | 2.18 | 2.67 | 3.45 | 17 |
40 | 235 | 950 | 1185 | 97.12 | 1.98 | 2.38 | 3.1 | 15 |
For further information on isolating and safety transformers for industrial applications, please call us on: 01444 243 452 or email: [email protected].