PCB Transformers

High performance single-phase PCB transformer provide reliability for use in critical ambients.

 

Six grey PCB Transformer devices.

Please note we are still adding products to our new website. Can't see the product you need? Contact us on 01444 243 452 / enquiries@gdrectifiers.co.uk

Expert technical support

Design Inspiration, whenever you need it

Custom & flexible ordering

Single Phase PCB Transformers

Safety transformers encapsulated with epoxy resin suitable for PCB use (T6-T7) or use in critical ambients

Meth Srl offers a comprehensive range of PCB transformers that provide safe electrical isolation for the input and output sides as a safety transformer. The single-phase PCB transformers are ENEC-KEMA and UL certified, providing high performance and reliability for use in critical ambients.

 

T5, T6 and T7

The T5, T6 and T7 are single-phase transformers encapsulated with epoxy resin suitable for PCB use (T6 and T7) or for use in critical ambients (T5).

 

Rated Input Voltage: from 100-250V

Rated Output Voltage: from 12-42V

Rated Power: T5: from 12-70VA

T6: from 3.2-100VA

T7: from 4-60VA

Insulation Class: class B

Temperature Class: class B

Ambient Temperature: Ta=70°C

Protection Degree: IP 00

Test Voltage: 4.2KV/1’

 

T5: input and output with 6.3mm faston

T6: for PCB insertion with pins with Ø 0 .8mm

T7: for PCB low profile with pins with Ø 0 .8mm

T5, T6 and T7 Datasheet

 

Standards

  • CEI-EN 61558, 2-6 – safety transformers
  • IEC 61558, 2-6 – safety transformers
  • UL-CSA 5085 1-2 – low voltage transformers

 

Certifications

  • ENEC-KEMA File: 3502609 03-04-05
  • UL Insulation System class B File E215141

 

T5 Technical Data

Part Number        Rated Power (VA)     Dimensions (mm)                   Weight (Kg)    Losses (W)  Efficiency (%)   ∆V (%) 
A B C D E no-load
T5-12 12 82 48 50 68 11 0.42 1 76 15
T5-20 20 82 54 54 74 13 0.56 1.2 87 14
T5-30 30 94 59 60 82 13 0.76 1.5 82 14
T5-35 35 94 59 71 82 36 1.04 2.2 85 9
T5-55 55 105 66 73 93 38 1.32 2.7 86 9.9
T5-70 70 105 66 83 93 48 1.54 3.5 87 8.8

 

T6 Technical Data

Part Number         Rated Power (VA)     Dimensions (mm)                   Weight (Kg)    Losses (W)  Efficiency (%)   ∆V (%) 
A B C D E F G no-load
T6-3.2 3.2 42 35.5 27.5 5 25 0.16 0.5 69 25
T6-4 4 43 37 33 5 25 0.18 0.9 69 25
T6-5 5 44.2 37.2 32 5 25 0.19 1 66 27
T6-10 10 50.2 42.2 34.5 5 27.5 0.28 1.2 71 24
T6-12 12 50.2 42.2 38.1 5 27.5 0.32 1.4 73 22
T6-16 16 74 47.5 40 65 5 32.5 0.42 1.6 72 24
T6-20 20 81.5 53.7 48 72.5 43.5 5 32.5 0.54 1.9 80 14
T6-25 25 81.5 53.7 53 72.5 43.5 5 32.5 0.62 2.2 81 13
T6-30 30 81.5 53.7 58 72.5 43.5 5 32.5 0.72 2.4 83 12
T6-35 35 87.5 53.7 58 78 48 5 35 0.78 2.6 84 12
T6-50 50 87.5 58.6 68 78 48 5 35 1.05 3.2 85 11
T6-60 60 102 58.6 65 90 57 7.5 39 1.35 3.4 86 11
T6-100 100 102 69 75 90 57 7.5 39 1.6 4.5 86 13

 

 T7 Technical Data

Part Number                Rated Power (VA)   Dimensions (mm)       Weight (Kg)    Losses (W)  Efficiency (%)   ∆V (%)
A B C no-load
T7-4 4 53 44 17.6 0.16 1.2 55 40
T7-6 6 53 44 22.6 0.18 1.1 63 33
T7-10 10 68 44 28.6 0.19 1.1 70 26
T7-14 14 68 57.5 24.2 0.28 1.6 70 26
T7-18 18 68 57.5 27.2 0.32 1.4 74 23
T7-24 24 68 57.5 31 0.42 1.7 76 21
T7-30 30 68 57.5 35.5 0.54 1.8 78 19
T7-40 40 83.5 69 37 0.62 2.2 78 19
T7-60 60 83.5 69 46 0.72 3.1 78 17

 

For further information on PCB transformers or to discuss your requirements, please call us on: 01444 243 452 or email: enquiries@gdrectifiers.co.uk.